46 Installation
Anti-intrusion control panels
3-10
Installing add-on boards
3-10-1
AUXREL32
If you intend installing this board, work carefully through the following steps.
1. Disconnect the primary power supply to the control (230V~) and the backup bat-
tery.
2. Insert the plastic supports into their respective locations (Table 2-6: Control pan-
els - description of parts, M) on the back of the metal enclosure.
3. Position the board holes on the supports and push the board towards the back of
the enclosure until it locks into position.
4. Insert the cable [A] into the connector [B].
5. Connect the two free wires of the cable [A] to terminals 14 (OC1) and 15 (OC2)
on the control panel motherboard. Ensure that OC1 and OC2 on the control panel
are appropriately connected (Table 2-43: AUXREL32 - description of parts, C).
6. Connect the wire [C] to the connector [D] and to the 2 free pins [E] of the con-
nector on the switching power-supply, as shown in the figure.
3-10-2
Flex5/U
The metal enclosures of SmartLiving 1050L, 10100L, 1050L/G3 e 10100L/G3 control
panels are capable of housing two Flex5/U [F] expansion boards (optional).
If you intend installing this type of board, work carefully through the following steps.
1. Disconnect the primary power supply to the control (230V~) and the backup bat-
tery.
2. Secure the plastic enclosure of the Flex5/U to the backplate of the control panel
(Table 2-6: Control panels - description of parts, N).
3. Connect it to BUS line as described in paragraph 3-2-1 The I-BUS line wiring.
4. Address it as described in paragraph 3-3-4 Addressing FLEX5 expansion boards.
5. Power up the control panel by reconnecting the mains power (230V
~) and backup
battery.
F
C
A
F
F
F
F
E
B
D
SmartLiving 10100L