Installation and programming manual
Options and programming methods 97
3° line: various indications depending on the device type:
- wired zone; resistance value reading expressed Ohm
- wireless zone; wireless signal reception level
- level of smoke present in the smoke detection chamber of the Air2-FD100
smoke detector, expressed in mdB/m
4° line: level of contamination present in the smoke detection chamber of Air2-FD100
smoke detector (%)
Note
It is advisable to clean the detector when the value exceeds 90%.
• Faults - allows you to view any current faults.
• Panel version - allows you to view the firmware version and model of the
SmartLiving control panel.
Outputs ON/OFF
Allows manual activation/deactivation of the outputs by means of keys and .
Set date/time
Allows you to set the date and time of the control panel.
1. Use key or to select the programming field you wish to change (hour, minutes,
etc.).
2. Use keys and to change the selected field.
3. Press to save and exit.
Via PC
The SmartLeague software programme provides a section which, during a connection to
a SmartLiving control panel, allows you to monitor the entire system in real time and
access some of the above-mentioned parameters.
Select the Check control panel, Monitoring option from the menu bar.
A window containing various sections will open. The sections can be selected by means
of tags, each referring to a different part of the system.
7-27
Other parameters
This option allows you to programme the advanced functions of the control panel.
Via Keypad
1. Access the “Other parameters” section.
Type-in Code
(Installer PIN)
, PROGRAMMING Other parameters .
2. Use keys and to select the parameter thenpress :
Periodic Ev.
This options allows you to select one of the four periodic events and set the respective
parameters.
• Time per. Event - this parameter allows you to set the time (hh/mm), day, month
and year of the first “Periodic event” (refer to paragraph 7-11 Events).
Table 7-20:
User functions - via SmartLeague software programme
Option Part of the system
Section of the monitoring
window
Template/section
View/Log
SmartLiving System - Events log Programming
View/Nexus status
Peripheral details - Sounder-
flashers, isolators and Nexus
Nexus
View/System status
Remote keypad Control panel status
Power Power supply parameters
View/Zone status
Zones
View/Faults present
Remote keypad Control panel status
View/Control panel version
Window heading
Outputs ON/OFF
Zones Outputs ON/OFF
Set date/time
SmartLiving System SmartLiving System Programming