98 Options and programming methods
Anti-intrusion control panels
Note
The time/date setting of this parameter must be later than the control panel clock setting.
PeriodicInterval - this parameter allows you to set the interval between each
“Periodic events” (expressed in hours).
To disable the “Periodic event”, set “0”.
Options:
•• Per.Ev Continuous - if enabled, the system will generate the corresponding
periodic event regardless of its initial date/time. The event will be generated
when the programming session is exited, or when the system starts up, and will
be generated continuously when the set period expires.
•• PeriodicEv InMin - if enabled, the interval (period of time) between two
consecutive activations (“Period.Ev.Time”) will be established in minutes and not
hours.
Mains fail.Delay
This parameter allows you to programme the delay, expressed in minutes (see note ),
between mains failure and the “Mains failure” fault event signal.
LocKpadMessTimes
The number of times voice messages, relating to events recorded at the keypad, will be
played (only for keypads with voice functions).
The playback phase can be stopped by pressing any key. If you set a value of “255” the
playback can be stopped by pressing any key, this is the only method of stopping
playback.
OverThePhoneVol.
This is the volume of the voice messages over-the-phone.
Ring sensitivity
This value determines the reception sensitivity of incoming call rings. This option is
useful in situations of bad reception (break up) or noisy lines.
At default this value is set at 60. Accepted values: 1 to 120.
Wireless superv.
This value determines the wireless-device supervision time. Once the pre-set time
expires, the devices which do not respond will be signaled as lost. Accepted values: 12
to 250 minutes (30 minutes at default).
Tel. input gain
This value determines the volume of the incoming call signal. This option is useful in
situations which require better comprehension of DTMF tones and improvement of
teleservice intervention via modem.
Adj. temperature
This parameter will allow you to enter the effective value of the room temperature read
by an external thermometer. This value will replace the keypad temperature reading
and thus allow you to correct the temperature sensor on the keypad you are working on
(valid for keypads with temperature sensors only).
The entered value must be expressed in °C decimals (for example, type in 252 if the
temperature is 25.2 °C).
LowBattery delay
This parameter allows you to programme the delay, expressed in minutes, which will be
applied before “LowBattery” events will be signalled.
LinedownDelay
This parameter allows you to programme the delay, expressed in seconds or minutes,
which will be applied before “LineDown” events will be signalled.
All the above-mentioned parameters can be programmed as follows.
3. Use keys and to select the field you wish to change, then use the number
keys ( , etc.) to edit the number.
or
Use keys and to increase or decrease the number.
FaultForNotReady
This section allows you to select which events, other than zones in alarm status, will be
signaled as system security-risk conditions when the partition arms.
If this value is
expressed in
minutes, there is
an error margin of
1 minute (for example, if
you set 5 minutes, the
period can vary between 4
and 5 minutes).
OverThePhoneVol.
00_ Units
(Min. 010)
(Max. 100)
Tel. input gain
00_ Units
(Min. 001)
(Max. 120)
If this value is
expressed in
minutes, there is an
error margin of 4
minutes (for example, if you
set 7 minutes, the period can
vary between 3 and 7
minutes).