EasyManua.ls Logo

INIM Electronics SmartLiving 10100L - Using the SmartLAN;G

INIM Electronics SmartLiving 10100L
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and programming manual
Installation 37
3-2-8
Installing nBy/S readers
The wall-mount nBy/S reader is suitable for indoor and outdoor installation.
Insert the two anchor screws [A] (included) into the two screw locations [B] on the
plastic backplate.
ATTENTION!
In order to avoid the risk of piercing the silicone seal [C], and thus jeopardizing the
waterproofing of the enclosure, insert the screws before fitting the seal.
3-2-9
Installing nBy/X readers
The Universal flush-mount nBy/X (Patent Pending) has been especially designed to
integrate with all brands of cover plates [A]. Drill two holes [B] for the light guide [C].
Use the adhesive drill-pattern (see opposite) to mark the drilling locations accurately.
1. Ensure that the centre of the cover plate coincides with the crossing of the axes x
and y on the drill-pattern. In this way, the two drilling locations (1 x 7mm diame-
ter and 1 x 8mm diameter) will be positioned precisely.
2. Using the screw [D], secure the reader components inside the cover plate.
3. Insert the cover plate (with the reader already assembled) into the light switch
box.
DISLODGEMENT TAMPER
The nBy/X reader is not equipped with built-in dislodgement-tamper protection.
However, the following section describes how you can protect nBy/X reader against this
kind of tamper.
In order to comply with Italian certification (Level 2 - IMQ Security Systems), all the
system peripherals must be protected against tamper. Installation of a microswitch will
allow the reader to signal tamper events. To obtain this type of protection, work
carefully through the following steps.
1. Use a microswitch with at least two normally-open contacts [A]. The one shown
in figure 3 has 3 contacts: COM-NO-NC.
2. Configure one of the terminals as follows: Input; 24H; Description = “Tamper
reader x”; single balancing with 6K8
W
[resistance [B]; unlimited alarm cycles.
Assign the duly programmed terminal to at least one keypad partition.
3. Using 2 wires, connect the microswitch to the 24H input terminal.
4. On the microswitch:
4.1. using one of the two wires, connect the common contact (COM) to the GND
terminal of the 24H terminal [C].
4.2. Connect the normally-open contact (NO) to one end of the 6k8
W
resistance [D]
(the normally-open contact generates a short-circuit between itself and the
COM contact when the microswitch-lever is compressed). Connect the other
end of the resistance to the wire which is connected to the 24h input terminal.
C
A
B
A
B
C
A
D
B
D
C
B
A