Installation and programming manual
The control panel and peripherals 13
Note
Use of the +AUX terminals on the mother board annuls standard 50131 - 3 compliance.
Table 2-8:
Mother board - description of parts
Models
505
515
1050
1050L
10100L
1050/G3
1050L/G3
10100L/G3
A
/
Connector for power-supply cable between power-supply unit
and control panel
B
Backup-battery connector Do not use
C
Thermal probe connector /
D
Thermal probe (enable/dis-
able) jumper
/
E
Connectors for the SmartLAN power-supply jumper
F
Local I-BUS connector Do not use
G
Maintenance jumper connectors
H
SmartLogos30M voice-board connector
I
Control panel to PC serial cable connector
J
Dislodgement-tamper microswitch connector (accessory item)
K
Open-panel tamper microswitch connector (accessory item)
L
Open-panel tamper microswitch
M
Terminal board
N
Blue and yellow activity LEDs
O
Firmware version label
P
Ground connection screws
Table 2-9:
Mother board - terminal board
n.
icon/identi-
fier
Model
505 515 1050 1050L 10100L
1
Earth connection
2-3
Internal telephone-line connection
4-5 PSTN
Land-line connection (PSTN)
6-7-8-9 + D S -
I-BUS connections
10-11-12 NO NC COM
Voltage-free contacts of the relay output
13
+AUX
+AUX1
12V Ancillary power supply
14-15 OC1 OC2
Open-collector output
16
+AUX
+AUX1
12V Ancillary power supply
17-19-21-
23-25
Power supply negative (earth or GND)
18-20-22-
24-26
T1-T2-T3-
T4-T5
Control panel input terminals: T1, T2, T3, T4 and T5
27
+AUX
+AUX2
12V Ancillary power supply
28-29 AC
Power supply input from
the transformer
28-30-32-
34-36
T6-T7-T8-
T9-T10
Terminals: T6, T7, T8, T9 and T10 of the
control panel
29-31-33-
35
Power supply negative (earth or GND)
37 +AUX3
12V Ancillary power supply
Table 2-10:
LIVPWR100 board - terminal board
n.
icon/identi-
fier
description
1-2-3-4 + D S -
I-BUS connections
5 +AUX1
12V Ancillary power supply
7 +AUX2
9 +AUX3
6-8-10
Power supply negative (earth or GND)
QC Passed
xx/xx/xx
FWINIESLIV15
LBFWINIESLIV15
x.00