20 The control panel and peripherals
Anti-intrusion control panels
Connection of the Alien/S keypad is achieved through the connector on the back and
must done using the 8 wire cable which comes with the keypad.
2-3-5
Readers - nBy/S and nBy/X
Reader terminals:
Table 2-25:
Alien/S - Connection wires
Wire
colour
Alien/S ter-
minal board
description
Red +
Cable/Terminal “
+
” of the I-BUS and RS485 BUS
Yellow D
Cable/Terminal “
D
” for the I-BUS connection
Green S
Cable/Terminal “
S
” for the I-BUS connection
Black -
Cable/Terminal “
-
” of the I-BUS and RS485 BUS
Grey B
Ter minal “
B
” for the RS485 BUS connection
Blue A
Ter m i n al “
A
” for the RS485 BUS connection
White REOL
Wire/Terminals to establish the EOL on the RS485
Table 2-26:
Alien - electrical and mechanical features
Keypad models Alien/S Alien/G
Voltage
from 9 to 16V
Typical current draw
150mA 400mA
Terminals configurable as
OC outputs
/2
Maximum current draw per
terminal
150mA
Input/Output terminals
/2
Display size
4.3 7
Number of display colours
65000
Display resolution
480x272 800x480
SD card capacity
16 GByte max.
Box for flush-mount
installation
Bracket for mounting to stan-
dard “503” boxes
Flush-mount box supplied
(214x129x54 mm)
Dimensions (W x H x D)
131x81x17mm
219x143x34mm
If mounted to flush-mount
box: 219x143x17
Weight
160g 520g
Alien/S - 8 wire cable
Table 2-27:
nBy - electrical and mechanical features
Reader models nBy/S nBy/X
Voltage
from 9 to 16V
Typical current draw
40mA 35mA
Dimensions (W x H x D)
64 x 80 x 17 mm 19 x 50 x 51 mm
Weight
45g 25g
Table 2-28:
nBy - description of parts
A
Terminal board
B
Buzzer (nBy/S only)
C
LED
D
Antenna
E
Optical sensors for open-enclosure and dislodgement tamper detection
Table 2-29:
nBy - terminal board
n.
icon/identi-
fier
description
1+
Ter m i n al “
+
” for the I-BUS connection
2D
Ter m i n al “
D
” for the I-BUS connection
3S
Ter minal “
S
” for the I-BUS connection
4-
Ter m i n al “
-
” for the I-BUS connection