5. Quick Setup
- 72 -
5
CONTINUE Para. Parameter name Default Commission
If AI3 is frequency reference
Set AI3 F4-23 AI curve 3 minimum input 0.00
If multi-reference is frequency
reference
0 V to F4-25;
F4-24 Corresponding percentage of AI3
minimum input
0.0
-100.0% to 100.0%
F4-25 AI3 maximum input 10.00
F4-23 to 10.00 V
F4-26 Corresponding percentage of AI3
maximum input
100.0
-100.0% to 100.0%
Set multi-reference FC-00 Reference 0 0.0
0.0 to 100.0%.
FC-01
to
FC-15
Reference 1-15 0.0
0.0 to 100.0%.
CONTINUE Para. Parameter name Default Commission