Installation
‑38‑
2.2.2 Installation Environment
Item
Requirement
Altitude
The maximum altitude is 5000 m.
Derating is not required for altitudes above 1000 m.
For altitudes above 1000 m, derate 1% for every additional 100 m.
For altitudes above 2000 m, contact Inovance.
Ambient
temperature
0°C to 40℃ (non‑freezing)
Storage
temperature
‑20°C to +60°C (Peak temperature: 80°C for 72 hours)
Ambient
humidity
20%–80% RH (without condensation)
Storage humidity
20%–90% RH (without condensation)
Vibration
Below 49 m/s
2
Shock
Below 490 m/s
2
IP rating
After wiring is done, the overall IP rating of the motor is as follows:
IP67 (shaft opening excluded, with power cables and encoder
connectors installed properly)
Installation
location
● Install the servo motor in a place free from corrosive and
inflammable gases and combustible materials, such as the
hydrogen sulfide, chlorine, ammonia, sulphur gas, chloridize gas,
acid, soda and salt.
● Use the servo motor with oil seal when the motor is to be used in
a place with grinding fluid, oil mist, iron powders or cuttings.
● Install the servo motor away from heating sources such as a
heating stove.
● Do not use the servo motor in an enclosed environment.
Running in an enclosed environment will lead to motor over‑
temperature, which shortens its service life.