Wiring
‑121‑
Note
The maximum permissible voltage and current capacity of the optocoupler output circuit
inside the servo drive are as follows:
● Maximum voltage: 30 VDC
● Maximum current: DC 50 mA
3.8.4 Encoder Frequency-Division Output Signals
For details on encoder frequency‑division output signals, see “
Table 3–9
”
on page 81
The encoder frequency‑division output circuit outputs differential signals through the
differential drive. Generally, this circuit serves to provide feedback signals to the host
controller in a position control system. Use a differential or optocoupler receiving
circuit on the host controller side to receive feedback signals. The maximum output
current is 20 mA.