Installation
50
Item
Description
Installation
direction
The servo motor can be installed horizontally or vertically.
Measures
against oil and
liquid
Do not submerge the motor/cable in water or oil.
Confirm the IP rating of the servo motor when the motor is to be
used in a place with water drops (excluding the shaft opening).
Install the motor with its connecting terminals facing downwards
(as shown in the following figure) when the motor is to be used in a
place with liquid. This is to prevent the liquid from flowing into the
motor along the cable.
In environments where the shaft opening is exposed to oil drops,
use a servo motor with an oil seal.
Observe the following requirements when using the servo motor
with an oil seal:
Make sure the oil level is lower than the oil seal lip during use.
Prevent oil accumulation on the oil seal lip when the motor is
installed vertically upward.