Installation
‑50‑
Item
Description
Installation
direction
The servo motor can be installed horizontally or vertically.
Measures
against oil and
liquid
● Do not submerge the motor/cable in water or oil.
● Confirm the IP rating of the servo motor when the motor is to be
used in a place with water drops (excluding the shaft opening).
● Install the motor with its connecting terminals facing downwards
(as shown in the following figure) when the motor is to be used in a
place with liquid. This is to prevent the liquid from flowing into the
motor along the cable.
● In environments where the shaft opening is exposed to oil drops,
use a servo motor with an oil seal.
● Observe the following requirements when using the servo motor
with an oil seal:
● Make sure the oil level is lower than the oil seal lip during use.
● Prevent oil accumulation on the oil seal lip when the motor is
installed vertically upward.