Wiring
‑61‑
Figure 3‑3 Wiring example of a three‑phase 380 V system
The servo drive is directly connected to an industrial power supply, with no
isolation such as a transformer. A fuse or circuit breaker therefore must be
connected to the input power supply to prevent electric shock in the servo system.
For the sake of safety, install a residual current device (RCD) to provide protections
against overload and short circuit or a specialized RCD to protect the grounding
cable.
Do not start or stop the motor by using the electromagnetic contactor. As a high‑
inductance device, the motor may generate high voltages instantaneously, which
may break down the contactor.
When connecting an external power supply to the control circuit or a 24 VDC
power supply, pay attention to the power capacity as insufficient power capacity

Table of Contents