Wiring
94
It is recommended to install the drive to a conductive metal surface. Ensure the
whole conductive bottom of the drive is connected properly to the mounting face.
Tighten the grounding screw with specified tightening torque to prevent the
protective grounding conductor from being secured improperly.
Single-drive grounding
Installation of an individual drive:
R S T
Table 3–16 Single‑drive grounding
No.
Description
Do not ground the DC bus terminal or the regenerative resistor terminal.
Connect the PE cable on the input power supply end to the input PE terminal
of the servo drive.
Connect the output PE terminal of the servo drive to the motor output cable
shield.
Input protection (fuse or circuit breaker)
Connect the lower end of the fuse to the filter.
Input power supply
Three‑phase motor