Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor
Tables
Revision 1.1
Intel order number G34153-003
139
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 1
DIMM
Aggregate
Thermal Margin
2
(P1 DIMM Thrm
Mrgn2)
B1h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
Processor 2
DIMM
Aggregate
Thermal Margin
1
(P2 DIMM Thrm
Mrgn1)
B2h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
Processor 2
DIMM
Aggregate
Thermal Margin
2
(P2 DIMM Thrm
Mrgn2)
B3h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
Processor 3
DIMM
Aggregate
Thermal Margin
1
(P3 DIMM Thrm
Mrgn1)
B4h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
Processor 3
DIMM
Aggregate
Thermal Margin
2
(P3 DIMM Thrm
Mrgn2)
B5h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A