Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSPlatform Management Overview
Revision 1.1 61
Intel order number G34153-003
4.4.4 Fan PWM Offset
This feature is reserved for manual adjustment to the minimum fan speed curves. The valid
range is from [0 to 100] which stands for 0% to 100% PWM adding to the minimum fan speed.
This feature is valid when Quiet Fan Idle Mode is at Enabled state. The default setting is [0].
4.4.5 Quiet Fan Idle Mode
This feature can be [Enabled] or [Disabled]. If enabled, the fan will either stopped or shift to a
lower speed when the aggregate sensor temperatures are satisfied indicating the system is at
ideal thermal/light loading conditions. When the aggregate sensor temperatures not satisfied,
the fan will shift back to normal control curves. If disabled, the fan will never stopped or shift into
lower fan speed whatever the aggregate sensor temperatures are satisfied or not. The default
setting is [Disabled]
Note:
1. The above features may or may not be in effective depends on the actual thermal
characters of a specific system.
2. Refer to System TPS for the board in Intel chassis thermal and acoustic management
3. Refer to Fan Control Whitepaper for the board in third party chassis fan speed control
customization.
4.4.6 Thermal Sensor Input for Fan Speed Control
The BMC uses various IPMI sensors as inputs to FSC. Some of the sensors are actual
physical sensor and some are virtual sensors derived from calculation.
The following IPMI thermal sensors are used as input to the fan speed control:
Front Panel Temperature Sensor
1
Baseboard Temperature Sensor
2
CPU Margin Sensors
3,5,6
DIMM Thermal Margin Sensors
3,5
Exit Air Temperature Sensor
1, 4, 8
PCH Temperature Sensor
4,6
On-board Ethernet Controller Temperature Sensors
4, 6
Add-In Intel SAS/IO Module Temperature Sensors
4, 6
PSU Thermal Sensor
4, 9
CPU VR Temperature Sensors
4, 7
DIMM VR Temperature Sensors
4, 7
iBMC Temperature Sensor
4, 7
Global Aggregate Thermal Margin Sensors
3, 8
Note:
1. For fan speed control in Intel chassis
2. For fan speed control in 3rd party chassis
3. Temperature margin from throttling threshold
4. Absolute temperature
5. PECI value
6. On-die sensor

Table of Contents

Other manuals for Intel S2600IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600IP and is the answer not in the manual?

Intel S2600IP Specifications

General IconGeneral
BrandIntel
ModelS2600IP
CategoryMotherboard
LanguageEnglish

Related product manuals