Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix C: Platform
Specific BMC Appendix
Revision 1.1
Intel order number G34153-003
155
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
6
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
Processor 1 Fan(36h)
7
BB P2 VR Temp(24h)
Exit Air Temp(2Eh)
P2 Therm Margin(75h)
Processor 2 Fan(37h)
HSC Availability
Not supported.
Power unit support
Intel
®
Server Chassis P4304 (UPL)
Table 80. Intel
®
Server Chassis P4304 (UPL) Power support
PS Module
Number
PMBus*
Product Name (in
product area of
the FRU)
PSU
Redundant
Cold
Redundant
Fans in
each PS
750W HS
Power Supply
Supported
DPS-750XB A
Supported
Supported
1 PS fan
1200W HS
Power Supply
Supported
DPS-1200TB A
Supported
Supported
2PS fan
Redundant Fans only for Intel
®
Server Chassis
Not supported.
Fan Fault LED support
Not supported.
Memory Throttling support
Baseboard supports this feature.

Table of Contents

Other manuals for Intel S2600IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600IP and is the answer not in the manual?

Intel S2600IP Specifications

General IconGeneral
BrandIntel
ModelS2600IP
CategoryMotherboard
LanguageEnglish

Related product manuals