Platform Management OverviewIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
72 Revision 1.1
Intel order number G34153-003
Non-critical, critical and non-
recoverable
Temperature sensor out of range
Non-critical, critical and non-
recoverable
Voltage sensor out of range
Non-critical, critical and non-
recoverable
General chassis intrusion
Chassis intrusion (security violation)
Failure and predictive failure
Watchdog Timer expiration for FRB2
Power down, power cycle, and reset
Drive Failure, Predicted Failure
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The “Diagnostic interrupt” action is not supported.
4.5.3.14 LAN Alerting
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps),
and SMTP email alerts.
The BMC supports a minimum of four LAN alert destinations.
4.5.3.14.1 SNMP Platform Event Traps (PETs)
This feature enables a target system to send SNMP traps to a designated IP address by means
of LAN. These alerts are formatted per the Intelligent Platform Management Interface
Specification Second Generation v2.0. A MIB file associated with the traps is provided with the
BMC firmware to facilitate interpretation of the traps by external software.
The format of the MIB file is covered under RFC 2578.
4.5.3.15 Alert Policy Table
Associated with each PEF entry is an alert policy that determines which IPMI channel the alert
is to be sent. There is a maximum of 20 alert policy entries. There are no pre-configured entries