Configuration Software and Utilities 73
Help Topics
The Help Topics menu has the following options:
Help Topics: Displays help information.
Enter New Password
Enter an EMP password. The valid range of characters includes ASCII values 32-126. The
password must be from 1-16 characters long.
Verify New Password
Enter the same password as above.
ESC Sequence
The ESC Sequence string is sent to the modem before sending a command string to the modem.
The length of the paging string is determined at run-time from firmware. You will be notified if the
string is truncated. The string that has been saved is the one that will be shown in the edit box.
Hangup String
The Hangup Line string is sent to the modem whenever the EMP wants to terminate the session.
The EMP automatically sends an <ENTER> character after this string. The length of the paging
string is determined at run-time from firmware. You will be notified if the string is truncated. The
string that has been saved is the one that will be shown in the edit box.
Modem Init String
The Modem Init String string is transmitted every time the EMP initializes. The length of the
paging string is determined at run-time from firmware. You will be notified if the string is
truncated. The string that has been saved is the one that will be shown in the edit box.
System Phone Number
Enter the system telephone number. This can be retrieved and reported via in-band management
connections.
Access Mode
In Pre-boot Only the EMP is automatically activated when the system is powered-down or hard
reset. In Always Active the EMP is active when the system is powered-down or hard reset. In
Disabled the EMP powers-up deactivated and is not automatically activated by BIOS, power-down
or hard resets.
Restricted Mode Access
When restricted mode is enabled control operations that could disable or alter a running system via
the EMP are disabled.
Connection Mode
Direct connect mode is for applications that connect the port directly to another computer system,
while Modem Mode is for applications where the port is connected to an external modem.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SCB2 - Server Board Motherboard and is the answer not in the manual?

Intel SCB2 - Server Board Motherboard Specifications

General IconGeneral
BrandIntel
ModelSCB2 - Server Board Motherboard
CategoryServer Board
LanguageEnglish

Related product manuals