152 xGen Lite Installation and Programming Guide
Appendix 1: System Status Messages
Various messages may appear on the Status screen of xGenLite Web Server
and UltraSync+ app.
System
AC power fail: The security system has lost its electricity power. May take up
to 5 min to clear once power restored.
Low battery: The security system’s back up battery requires charging. May
take up to 5 min to clear once battery charged.
Battery test fail: The security system’s back up battery requires changing. If
after 48 hours this message does not clear, replace with a new battery. If the
power fails, the system will not be operational.
Box tamper: The security system’s cabinet tamper input has activated.
Siren trouble: The security system’s external siren has a problem. Check the
panel is securely installed on the wall.
Over current: The security system is drawing too much current. Disconnect
some hardwired inputs.
Time and date loss: The security system time and date need resetting.
Communication fault: The security system has detected a problem with the
communication channel. Check the internet connection, Ethernet cable, or
cellular reception is sufficient.
Fire alarm: A fire alarm has been activated from the panel.
Panic: A panic alarm has been activated from the panel.
Auxiliary: An auxiliary alarm has been activated from the panel.
Area Number. Area Name
Is on in the away mode: This Area is armed in the away mode.
Is on in the stay mode: This Area is armed in the stay mode.
Is ready: This Area is secure and ready to be armed.
Is not ready: This Area is NOT ready to be armed, a zone is not secure.
All Areas are on in the away mode: All Areas in this multi area system are
armed in the away mode.
All Areas are on in the stay mode: All Areas in this multi area system are
armed in the stay mode.
All Areas are ready: All Areas in this multi area system are secure and ready
to be armed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NXG-4-RF-BO and is the answer not in the manual?

Interlogix NXG-4-RF-BO Specifications

General IconGeneral
BrandInterlogix
ModelNXG-4-RF-BO
CategorySecurity Sensors
LanguageEnglish

Related product manuals