EasyManuals Logo

Interlogix NXG-4-RF-BO User Manual

Interlogix NXG-4-RF-BO
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
12 xGen Lite Installation and Programming Guide
#
SIA code
CID code
Function
157
YQ
R351
Power Supply Restore
EN 50131-3 and EN 50136-2 Compliancy
In order to be compliant with the technical specification EN 50131-3 (Alarm
systems Control and indicating equipment), the following guidelines must be
taken into account:
The tamper of the warning device should be connected to a 24-hour zone
input.
Overriding is not supported with xGenLite. In case a zone is faulted, one shall
bypass the zone manually before arming or verify the zone and clear the fault.
See user instructions.
Hold-up zones are not allowed to be set for bypass.
Zone isolation is not supported.
EN 50136-2 (Alarm transmission systems and equipment Part 2:
Requirements for Supervised Premises Transceiver (SPT):
- Upon configuring alarm transmission path and remote connection details,
default user/installer keys shall be changed.
- Minimum PIN length is 6 digits.
Options Affected by EN 50131 Regulations
EN 50131 Grade 2 Required settings
The following options and values are mandatory for EN 50131-1 Grade 2
regulations.
Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet
Class 4.
View Areas and Control Areas settings are identical
Buzzer silent, never
Quick set, off
Function keys, all set to None
User group options, 25. No OP/CL reports option set to No
Inhibit, set to No for all zones with type 5. Panic, 6. 24H
Swinger shunt, set to Yes for all zones
ACK on keypad, set to None for all zones with type 9. Keyswitch
Entry time, 45 s maximum
Entry alarms, Instant
Active, set to No for all schedules.
Activation, internal and external siren 90 to 900 s
Delay time, external siren 600 s maximum
Armed display, 30 s maximum

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NXG-4-RF-BO and is the answer not in the manual?

Interlogix NXG-4-RF-BO Specifications

General IconGeneral
BrandInterlogix
ModelNXG-4-RF-BO
CategorySecurity Sensors
LanguageEnglish

Related product manuals