Chapter 3 — Developing and Using RFID Applications
IF61 Fixed Reader User’s Manual 67
Session
(EPCglobal Class 1 Gen 2 tags only) Sets the command session
parameter to the corresponding EPCglobal Class 1 Gen 2 air
protocol command (default is QueryAdjust).
This setting is equivalent to the SESSION BRI attribute. For
more information on this setting, see the EPCglobal Class 1 Gen
2 documentation.
Initial Q
(EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter
value used by the Query command. Valid range is 0 to 15
(default is 4). If you know there is only one tag in the field, set
this attribute to 0 for best performance.
This setting is equivalent to the INITIALQ BRI attribute.
Initialization Tries
Sets the maximum number of times the reader attempts to
initialize a tag. Valid range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.
ID Tries
Sets the maximum number of times the reader executes the
identify algorithm before a response is returned to a Read or
Write command.
In practice, this is the number of times a tag ID attempt is made
for each antenna being used. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the IDTRIES BRI attribute.
ID Timeout
Sets the ID timeout value (in ms) when Timeout Configuration
mode is enabled. Range is 0 to 65534 (default is 100). This
setting is visible only if Timeout Configuration mode has been
enabled. For help, see “Timeout Configuration Mode” in this
section.
This setting is equivalent to the IDTIMEOUT BRI attribute.
Antenna Tries
Sets the maximum number of ID Tries that the reader executes
per antenna. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the ANTTRIES BRI attribute.