10
/74
IRMA MATRIX
R2 CAN Installation manual
released
Rev. 1.6
2018-09
2 Important information when working with IRMA
MATRIX sensors
IRMA MATRIX sensors must only be installed by qualified expert staff trained by iris-GmbH
who observe the pertinent regulations and the installation manual.
2.1.1 New service software version required
Before starting the configuration of the IRMA MATRIX sensors, perform an update of the
"DIST500-Configuration Tool" service software to version "3.9.6.187" or higher. For more
detailed information on the software update see section 8.2.1 on p. 47.
2.1.2 Firmware
Important note:
Please bear the following in mind for firmware updates via an on-board computer!
Firmware versions having "1" as the first Fig. of the version designation must not be
installed any more.
The sensor firmware is continuously developed in order to keep up with technological
progress. As downward compatibility with the predecessor version is ensured from
firmware versions with "2" as the first Fig. on, different firmware versions in different
deliveries are by no means a functional restriction. The latest firmware version is: D5FC -
DIST500_Application_2.1.312.6797 - CE_CF_D0_D1_D4_D5.d5fc.
If a consistent firmware version is to be ensured for one order comprising several
deliveries, please indicate this requirement when placing your order.
2.1.3 Comparison of old and new counting firmware
The new firmware file
D5FC-DIST500_Application_2.1.312.6797-CE_CF_D0_D1_D4_D5
added new parameters to the “Ethernet” and “Installation” tabs.
In the old firmware
D5FC-DIST500_Application_2.0.0.5072 Single Count Category-
3521_CE_CF_D0_D1_D4_D5
In all considerations with regard to installation positions and orientation, it is assumed
that the observer is inside the vehicle.