IRMA
MATRIX R2 CAN Installation manual
released
Rev. 1.6
2018-09
Fig.
45: Sensor installation in a 4-door vehicle with sCON-S (standard) for CAN - IRMA gateway in the center (M12 connector)
1
Fuse 5 A, quick-acting
2
Power cable with M12 cnnector (f), type CAN/
2 wires and shield
K-M12POW-B-04-2m or K-M12POW-B-oE-04-2m;
or
Connecting cable, CAN type with M12 connector (f), type CAN/
4 wires and shield; K-M12CAN-B-01-1m
3
SUB-D9 M12 adapter, CAN type
without terminator, without power supply
K-A21-M12CAN-oP-01-32cm
4
IRMA gateway: IRMA-Gateway-x-xxxx
5
M12 H coupler of the CAN type, M12CAN-CON-03
6
M12 extension cable, CAN type; K-M12CAN-XX-x
7
M12 termination connector (m), CAN type; M12CAN-TR-02
8
sCON-S for MATRIX sensors on the CAN BUS
sCON-S-CAN-20-Kn-1m
9
IRMA MATRIX sensor DIST500-F (flush mount version)
10
M12 screw plug; M12CAN-CON-04
11
Power supply connection (P) e.g.: K-A21-P-01-15m
12
OBC/door contact connection (V)
e.g.: K-A21-V-IBIS-07-15-15-15-15-15m
M12 connector (male), CAN type
M12 connector (female), CAN type
D1
- D4 Doors with one sensor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IRIS IRMA MATRIX 2 and is the answer not in the manual?

IRIS IRMA MATRIX 2 Specifications

General IconGeneral
BrandIRIS
ModelIRMA MATRIX 2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals