Chapter 2 Functions for Each Mode
SEAL HEATER TEMPERATURE(°C): Configures the film sealing heater temperature.
(Value range: 80 to 170)
POWER: Switches on/off the film sealing heater power.
FAN HEATER TEMPERATURE(°C): Configures the fan heater temperature.
(Value range: 0 to 40°C)
POWER: Switches on/off the fan heater power.
FILM TENSION Adjusts the film tension. Enter a relative value. (Value range: -4 to +4)