3-phase/series commands
Copyright© Itech Electronic Co., Ltd. 92
Query Syntax
PROTect:RMS:CURRent? <A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
PROTect:PEAK:CURRent
This command is used to set the OCPpeak value.
Syntax
PROTect:PEAK:CURRent <A|B|C|ALL>,<NRf>
Arguments
<A|B|C|ALL>,<NRf>
Query Syntax
PROTect:PEAK:CURRent? <A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
PROTect:RMS:CURRent:TIME
This command is used to set the delay time of OCP.
Syntax
PROTect:RMS:CURRent:TIME <A|B|C|ALL>,<NR1>
Arguments
<A|B|C|ALL>,<NR1> 0 ~ 9999 ms
Query Syntax
PROTect:RMS:CURRent:TIME? <A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
PROTect:POWer
This command is used to set the delay time of OCP.