SOURce Subsystem(IT-M7700)
Copyright© Itech Electronic Co., Ltd. 54
Syntax
[SOURce:]NORMal:SURGETRAP:PERIOD <NR1>
Arguments
<NR1> 1 ~ 999 (cycle)
Query Syntax
[SOURce:]NORMal:SURGETRAP:PERIOD?
Returns
<NR1>
[SOURce:]NORMal:SURGETRAP:WIDTH
The command is used to set the surge/trap width.
Syntax
[SOURce:]NORMal:SURGETRAP:WIDTH <NRf>
Arguments
<NRf> 0.01 ~ 100.00mS
Query Syntax
[SOURce:]NORMal:SURGETRAP:WIDTH?
Returns
<NRf>
[SOURce:]NORMal:SURGETRAP:PERCENT
The command is used to set the percentage of the surge/trap amplitude to AC
signal amplitude(rms).
Syntax
[SOURce:]NORMal:SURGETRAP:PERCENT <NRf>
Arguments
<NRf> 0 ~ 500.0%