3-phase/series commands
Copyright© Itech Electronic Co., Ltd. 101
FETCh[:SCALar]:POWer:REACTive?
This command reads the reactive power.
Syntax
FETCh[:SCALar]:POWer:REACTive? <A|B|C|ALL>
Arguments
<A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
MEASure[:SCALar]:VOLTage:AC?
This command reads the Vrms value.
Syntax
MEASure[:SCALar]:VOLTage:AC? <A|B|C|ALL>
Arguments
<A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
MEASure[:SCALar]:CURRent:AC?
This command reads the Irms value.
Syntax
MEASure[:SCALar]:CURRent:AC? <A|B|C|ALL>
Arguments
<A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>