SOURce Subsystem
Copyright© Itech Electronic Co., Ltd. 45
Arguments
<NRf>
Query Syntax
[SOURce:]NORMal:VOLTage:AC:MAX[:LEVel]?
Returns
<NRf>
[SOURce:]NORMal:VOLTage:AC:MIN[:LEVel]
This command sets the minimum AC voltage of the power supply.
Syntax
[SOURce:]NORMal:VOLTage:AC:MIN[:LEVel] <NRf>
Arguments
<NRf>
Query Syntax
[SOURce:]NORMal:VOLTage:AC:MIN[:LEVel]?
Returns
<NRf>
[SOURce:]NORMal:VOLTage:DC:MAX[:LEVel]
This command sets the maximum DC voltage of the power supply.
Syntax
[SOURce:]NORMal:VOLTage:DC:MAX[:LEVel] <NRf>
Arguments
<NRf>
Query Syntax
[SOURce:]NORMal:VOLTage:DC:MAX[:LEVel]?
Returns
<NRf>