3-phase/series commands
Copyright© Itech Electronic Co., Ltd. 95
Arguments
<A|B|C|ALL>,<NRf>
Query Syntax
PROTect:RMS:CURRent:MIN[:LEVel]? <A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
[SOURce:]NORMal:CURRent:RANGe
This command is used to set the current range of the power supply.
Syntax
[SOURce:]NORMal:CURRent:RANGe <A|B|C|ALL>,<0|1|2|AUTO|HIGH|LOW>
Arguments
<A|B|C|ALL>,<0|1|2|AUTO|HIGH|LOW>
Query Syntax
[SOURce:]NORMal:CURRent:RANGe? <A|B|C|ALL>
Returns
<0|1|2|AUTO|HIGH|LOW>
[SOURce:]RELAy:MODe
This command is used to set the relay mode.
Syntax
[SOURce:]RELAy:MODe <A|B|C|ALL>,<0|1|OUTSYN|NC>
Arguments
<A|B|C|ALL>,<0|1|OUTSYN|NC>
OUTSYN: The relay is linked with Output; NC:The relay is normally closed.
Whether
Query Syntax
[SOURce:]RELAy:MODe? <A|B|C|ALL>,