STATus Subsystem
Copyright© Itech Electronic Co., Ltd. 18
STATus:OPERation[:EVENt]?
Queries the event register for the Operation Status group. This is a read-only
register, which stores (latches) all events that are passed by the Operation NTR
and/or PTR filter. Reading the Operation Status Event register clears it.
Query Syntax
STATus:OPERation[:EVENt]?
Arguments
None
Returns
<NR1>
Related Command
STATus:OPERation:ENABle
The following table describes the Operation Status register bit assignments.
Bit
7
6
5
4
3
2
1
0
Name
n.u
n.u
n.u
n.u
DIMMER
SURGE
LIST
CAL
Decimal
Value
8
4
2
1
STATus:OPERation:CONDition?
Queries the condition register for the Operation Status group. This is a
read-only register, which holds the live (unlatched) operational status of the
instrument. Reading the Operation Status Condition register does not clear it.
Query Syntax
STATus:OPERation:CONDition?
Arguments
None
Returns
<NR1>
The value returned is the binary-weighted sum of all bits set in the register.

Table of Contents

Other manuals for ITech IT-M7700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M7700 Series and is the answer not in the manual?

ITech IT-M7700 Series Specifications

General IconGeneral
BrandITech
ModelIT-M7700 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals