SOURce Subsystem
Copyright© Itech Electronic Co., Ltd. 44
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate]
This command sets the DC voltage of the power supply.
Syntax
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate] <NRf>
Arguments
<NRf>
Query Syntax
[SOURce:]NORMal:VOLTage:DC[:LEVel][:IMMediate]?
Returns
<NRf>
[SOURce:]NORMal:FREQuency[:LEVel][:IMMediate]
This command sets the AC frequency of the power supply.
Syntax
[SOURce:]NORMal:FREQuency[:LEVel][:IMMediate] <NRf>
Arguments
<NRf>
Query Syntax
[SOURce:]NORMal:FREQuency[:LEVel][:IMMediate]?
Returns
<NRf>
[SOURce:]NORMal:VOLTage:AC:MAX[:LEVel]
This command sets the maximum AC voltage of the power supply.
Syntax
[SOURce:]NORMal:VOLTage:AC:MAX[:LEVel] <NRf>