3-phase/series commands
Copyright© Itech Electronic Co., Ltd. 96
Returns
<OUTSYN|NC>
[SOURce:]NORMal:OFFTIMER:MODe
This command is used to set the output timer function.
Syntax
[SOURce:]NORMal:OFFTIMER:MODe <A|B|C|ALL>,<0|1|OFF|ON>
Arguments
<A|B|C|ALL>,<0|1|OFF|ON>
Query Syntax
[SOURce:]NORMal:OFFTIMER:MODe? <A|B|C|ALL>
Returns
<OFF|ON>
[SOURce:]NORMal:OFFTIMER
This command is used to set the setting value of output timer (unit: ms).
Syntax
[SOURce:]NORMal:OFFTIMER <A|B|C|ALL>,<NR1>
Arguments
<A|B|C|ALL>,<NR1> 10~10000000
Query Syntax
[SOURce:]NORMal:OFFTIMER?
Returns
<NR1|NR1|NR1|NR1,NR1,NR1>
PROTect:CLEar
This command clears the protection status.
Syntax
PROTect:CLEar <A|B|C|ALL>