SCPI Command Introduction
Copyright© Itech Electronic Co., Ltd. 10
etc. Special values of numerical parameter are also acceptable, such as MIN,
MAX and DEF. In addition, suffixes for engineering units can also be sent
together with numerical Parameter (including M, k, m or u). If the command
accepts only some specific values, the instrument will automatically round the
input parameter to acceptable values. The following commands require
numerical Parameter of frequency value:
[SOURce[1|2]:]FREQuency:CENTer {<Frequency>|MINimum|MAXimum}
<NR1>: represents an integer value, such as 273;
<NR2>: represents a real number in floating-point format, such as
0.273;
<NR3>: represents a real number in scientific notation, such as
2.73E+2;
<Nrf>:The extensible form includes <NR1>, <NR2> and <NR3>;
<Nrf+>: The extensible decimal form includes <NRf> and MIN MAX
DEF, MIN and MAX represent the minimum and maximum finite
number. DEF is the default of the parameter.
Discrete parameter
Discrete Parameter are used for settings with limited number of programming
values (such as IMMediate, EXTernal or BUS). They can use short and long
format like key words of commands. They may be expressed in both upper and
lower case. The query response always returns uppercase Parameter in short
format. The following commands require discrete Parameter in voltage unit:
[SOURce[1|2]:]VOLTage:UNIT {VPP|VRMS|DBM}
Boolean parameter
Boolean Parameter refer to true or false binary conditions. In case of false
conditions, the instrument will accept "OFF" or "0". In case of true conditions,
the instrument will accept "ON" or "1". In query of Boolean settings, the
instrument will always return "0" or "1". Boolean Parameter are required by the
following commands:
DISPlay {OFF|0|ON|1}
ASCII string Parameter
String Parameter may actually include all ASCII character sets. Character
strings must start and end with paired quotation marks; and single quotation
marks or double quotation marks are both allowed. Quotation mark separators
may also act as one part of a string, they can be typed twice without any
character added between them. String parameter is used in the following

Table of Contents

Other manuals for ITech IT-M7700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M7700 Series and is the answer not in the manual?

ITech IT-M7700 Series Specifications

General IconGeneral
BrandITech
ModelIT-M7700 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals