91
C28 Display & clear error record
Options:
0 : Do not clear the error memory
1 : Clear the error memory.
Special function: none
Description: The last 10 different malfunction codes are written into the error memory so that they can be called
up and reported by the operator of the wheel balancer e.g. for remote diagnosis of malfunctions. The most recent
malfunction code is written into memory location 1 and the previous error codes are shifted to the higher memory
locations.
Display of internal error code (6 digits).
Use the option selection to proceed to the next error message (reading Err1 -Err10). If no error occurred, "---"
is read out.
Clearing the entire error memory (step 2):
Press the Acknowledgment key to proceed to step 2.
Use the option selection to choose “1” and acknowledge with the Acknowledgment key.
Comments: None
C43 Reset counters
Options.
0 : No reset of counters
1 : Reset of counters.
Special function: None
Description: During ! rst setting into operation in the factory the following counters and memories can be reset
simultaneously using this code:Total number of measuring runs
• Number of measuring runs where balance quality was considered OK
• Number of optimisations and minimisations
• Number of measuring runs in service mode
• Number of measuring runs since the last calibration
The error memory which can be called up using C28 will not be reset. To this end please use C28.
Comments: None
C45 Unbalance Calculation Parameters
Options:
Press “Enter” button to switch from step to step.
Pres +/- button to enable/disable th step
Special function: None
Description: This C code de! ne the start mode and automatically the necessary number of revolution for
measurement.
The Special function can be read out one below the other:
In step 1: The balancing time is reduce automatically in case the machine is able to measure it in the ! rsts revolutions
of the spin.
0 : Disable the Adaptive Measuring Cycle
1 : Enable the Adaptive Measuring Cycle
In step 2: Alternative algoritm to measure the 1st Harmonic of the unbalance.Faster then the previousi Fourier.
0 : Disable the Goertzel algorithm
1 : Enable the Goertzel algorithm