ņ23 
[I]    Method of Displaying Target Data [TGT DATA] 
 
 
  Procedure    1  Move the cross cursor mark onto the target for which numeric data is to 
be displayed, and press the [TGT DATA] key. 
  Or, set the cursor mode to TGT Data, place the cross cursor over the 
target whose numerical data is to be displayed, and press the [ENT] key. 
 
Then, the data of the designated target will appear, it will be marked with a symbol “
 
”.   
The target data will remain on the radar display until the target is lost and its vector 
disappears, or until another target is designated. 
If a target with the mark “
 
” is designated, only its true bearing (BEARING) and range 
(RANGE) will appear until its vector appears. 
 
 
 
[II]    Canceling numerical data display (CNCL Data) 
 
 
  Procedure    1  Set the cursor mode to TGT Data, place the cross cursor over the tracked 
target whose numerical data is to be displayed, and press the [CLR/INFO] 
key. 
 
Numerical data display is canceled.