8.4.1 Parts Expected for Periodic Replacement
Here are parts expected for periodic replacement
Part name Interval
1. Magnetron 4000 hours
2. Motor 10000 hours
3. LCD backlight 50000 hours
4. Fan motor 20000 hours
5. Backup battery 5 years
8.4.2 Replacement of magnetron
Before replacing the magnetron, turn off the main power source, wait for five minutes or more, and confirm
that no charge remains in the high-voltage modulator circuit.
When mounting a new magnetron, do not touch the magnet with a screwdriver or put it on an iron plate. After
replacement, connect the lead wire correctly.
Handling of Magnetron under Long-Time Storage
The magnetron that has been kept in storage for a long time may cause sparks and operate unstably when its
operation is started. Perform the aging in the following procedure:
(1) Warm up the cathode for a longer time than usually. (20 to 30 minutes in the STBY state.)
(2) Start the operation from the short pulse range and shift it gradually to the longer pulse ranges. If the
operation becomes unstable during this process, return it to the standby mode immediately. Keep the
state for 5 to 10 minutes until the operation is restarted.

Table of Contents

Other manuals for JRC JMA-5208HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5208HS and is the answer not in the manual?

JRC JMA-5208HS Specifications

General IconGeneral
BrandJRC
ModelJMA-5208HS
CategoryMarine Radar
LanguageEnglish

Related product manuals