Alarm for New Target Acquired in Automatic Acquisition Zone (New Target)
CAUTION
In setting an automatic acquisition zone, it is necessary to
adjust the gain, sea clutter suppression and rain clutter
suppression to ensure that target echoes are displayed in
the optimum conditions. No automatic acquisition zone
alarms will be issued for targets undetected by the radar,
and this may cause accidents such as collisions.
The automatic acquisition function sets a zone in a range and issues an alarm when a new target (which is
not yet acquired) goes into this zone.
For the setting of an automatic acquisition zone, refer to " Acquiring Target " in Section 5.2.1.
Alarm for New Target Acquired in Automatic Acquisition Zone
Status Symbol on display Alarm characters Alarm sound Conditions
New target in
automatic
acquisition
zone
Red Blinking
New Target
Beep sound (pipi-pipi)
Alarm
acknowledgeable
The alarm is issued when
a new target is acquired
in the automatic
acquisition zone.
Note: When an already acquired target goes into automatic acquisition zone, the alarm message
is not displayed and the buzzer does not sound either.
5-47

Table of Contents

Other manuals for JRC JMA-5312-6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5312-6 and is the answer not in the manual?

JRC JMA-5312-6 Specifications

General IconGeneral
BrandJRC
ModelJMA-5312-6
CategoryMarine Radar
LanguageEnglish

Related product manuals