7.4.4 Clear and Save/Restoration of Antenna Operation Time
(TXRX Time)
The system adds up the following operation time and contains it in the antenna unit:
• Transmission time
• Motor run time
Clear the above total time when the magnetron or antenna unit motor is replaced.
[I] Clear of Transmission Time (Clear TX Time)
Clear the transmission time of the antenna unit.
Perform the following procedure to clear the transmission time when the magnetron is replaced.
Procedures 1. Open the Serviceman Menu.
2. Open the Clear TX Time menu by performing the following menu
operation.
3. Maintenance Menu
→ 5. TXRX Time
→ 1. Clear TX Time
3. Select Yes in the Confirmation Window.
The transmission time in the antenna's internal control circuit is cleared to 0.
[II] Clear of Motor Run Time (Clear Motor Time)
Clear the antenna's motor run time.
Perform the following procedure to clear the motor run time when the antenna motor is replaced.
Procedures 1. Open the Serviceman Menu.
2. Open the Clear Motor Time menu by performing the following menu
operation.
3. Maintenance Menu
→ 5. TXRX Time
→ 2. Clear Motor Time
3. Select Yes in the Confirmation Window.
The motor run time in the antenna's internal control circuit is cleared to 0.
7-41

Table of Contents

Other manuals for JRC JMA-5312-6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5312-6 and is the answer not in the manual?

JRC JMA-5312-6 Specifications

General IconGeneral
BrandJRC
ModelJMA-5312-6
CategoryMarine Radar
LanguageEnglish

Related product manuals