9 Technical data
87
9.6 Relay output (extra code)
9.7 Display
Designation Function
Limit value relay output Relay (changeover contact)
Contact protection circuit: Fuse cut-out 3.15 AT installed in pin branch
30,000 switching operations at a switching capacity of AC 240 V, 3 A, 50 Hz (resistive load) or
maximum DC 30 V, 3 A. Minimum current: DC 12 V, 100 mA
Type, resolution Dot-matrix LCD display with 64 × 96 pixels
Brightness setting Contrast can be adjusted on device, background lighting can be switched off via timeout