9 Technical data
80
9 Technical data
9.1 Analog input
9.1.1 RTD temperature probe
Designation Standard Measuring range Measuring accura-
cy
a
T
K
ITS
Pt50
2/3-wire circuit
4-wire circuit
GOST 6651-2009 A.2
-200 to +850 °C
-200 to +850 °C
±0.5 K
±0.3 K
3.91×10
-3
1/K 90
Pt100
2/3-wire circuit
4-wire circuit
IEC 60751:2008
-100 to +200 °C
-200 to +850 °C
-100 to +200 °C
-200 to +850 °C
±0.2 K
±0.4 K
±0.1 K
±0.2 K
3.85×10
-3
1/K 90
Pt500, Pt1000
2/3-wire circuit
4-wire circuit
IEC 60751:2008
-100 to +200 °C
-200 to +850 °C
-100 to +200 °C
-200 to +850 °C
±0.2 K
±0.4 K
±0.1 K
±0.2 K
3.85×10
-3
1/K 90
Ni100, Ni500, Ni1000
2/3-wire circuit
3-wire circuit
DIN 43760:1987-09
-60 to +250 °C
-60 to +250 °C
±0.4 K
±0.2 K
6.18×10
-3
1/K IPTS-68
Ni100
2/3-wire circuit
3-wire circuit
GOST 6651-2009 A.5
-60 to +180 °C
-60 to +180 °C
±0.4 K
±0.2 K
6.18×10
-3
1/K 90

Table of Contents