Figure 8: Fan Status LEDs on the Router
g009498
1
1Fan status LEDs
The fan status LED is a bicolor LED. Table 8 on page 32 describes the behavior of the fan status LED.
Table 8: Fan Status LED
DescriptionStateColor
Fan module hardware initialization is complete and software initialization is
pending.
BlinkingGreen
Software initialization is complete and the fan is functioning normally.On
steadily
Fan module is faulty and not functioning normally.On
steadily
Red
Fan module not presentOff
SEE ALSO
Replacing an MX204 Fan Module | 124
Maintaining the MX204 Fan Module | 122
MX204 AC Power System
IN THIS SECTION
MX204 Power System Description | 33
MX204 Power Supply Module LEDs | 35
MX204 Router AC Power Specifications | 38
32

Table of Contents

Other manuals for Juniper MX204

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX204 and is the answer not in the manual?

Juniper MX204 Specifications

General IconGeneral
Cooling typeActive
Product colorGray
Rack capacity1U
Rack mountingYes
Number of fans3 fan(s)
AC input voltage100 - 240 V
Number of power supply units2
Operating altitude0 - 1828 m
Operating temperature (T-T)0 - 55 °C
Operating relative humidity (H-H)5 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth475 mm
Width447 mm
Height44.5 mm
Weight10500 g