DC Power Cable Specifications for MX204 Router
IN THIS SECTION
DC Power Cable Lug Specifications | 45
DC Power Cable Specifications | 45
DC Power Cable Lug Specifications
The accessory box shipped with the router includes the cable lugs that attach to the terminal of each
power supply.
Figure 15: DC Power Cable Lug
g009544
.170 max
wire diameter
(insulation)
.84
.71
.25
.15 dia
All measurements in inches
CAUTION: Before router installation begins, a licensed electrician must attach a cable
lug to the grounding and power cables that you supply. A cable with an incorrectly
attached lug can damage the router.
DC Power Cable Specifications
You must supply four DC power cables that meet the following specifications: 14-16 AWG (2.08 - 1.3 mm
2
),
minimum 60° C wire, or as required by the local code.