DC Power Cable Specifications for MX204 Router
IN THIS SECTION
DC Power Cable Lug Specifications | 45
DC Power Cable Specifications | 45
DC Power Cable Lug Specifications
The accessory box shipped with the router includes the cable lugs that attach to the terminal of each
power supply.
Figure 15: DC Power Cable Lug
g009544
.170 max
wire diameter
(insulation)
.84
.71
.25
.15 dia
All measurements in inches
CAUTION: Before router installation begins, a licensed electrician must attach a cable
lug to the grounding and power cables that you supply. A cable with an incorrectly
attached lug can damage the router.
DC Power Cable Specifications
You must supply four DC power cables that meet the following specifications: 14-16 AWG (2.08 - 1.3 mm
2
),
minimum 60° C wire, or as required by the local code.
SEE ALSO
45

Table of Contents

Other manuals for Juniper MX204

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX204 and is the answer not in the manual?

Juniper MX204 Specifications

General IconGeneral
Cooling typeActive
Product colorGray
Rack capacity1U
Rack mountingYes
Number of fans3 fan(s)
AC input voltage100 - 240 V
Number of power supply units2
Operating altitude0 - 1828 m
Operating temperature (T-T)0 - 55 °C
Operating relative humidity (H-H)5 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth475 mm
Width447 mm
Height44.5 mm
Weight10500 g