LI - Input Parameters
LI03 = B(Inspection - Level - Correction), NUM = 1
US04
Binary Speed
Selection
Parameter
Control Inputs
I2 I3 I4
S
ZERO
- 0 0 0
S
LEVELING
LS01 0 1 0
S
HIGH
LS02 0 0 1
S
INSPECTION
LS03 1 0 0
S
CORRECTION
LS04 1 1 0
S
INTERMEDIATE 1
LS05 1 0 1
S
INTERMEDIATE 2
LS06 0 1 1
S
INTERMEDIATE 3
LS07 1 1 1
LI03 = B(Level - Correction - High), NUM = 2
US04
Binary Speed
Selection
Parameter
Control Inputs
I2 I3 I4
S
ZERO
- 0 0 0
S
LEVELING
LS01 1 0 0
S
HIGH
LS02 1 1 0
S
INSPECTION
LS03 0 0 1
S
CORRECTION
LS04 0 1 0
S
INTERMEDIATE 1
LS05 1 0 1
S
INTERMEDIATE 2
LS06 0 1 1
S
INTERMEDIATE 3
LS07 1 1 1
LI03 = Decode with LI16
Refer to LI16 Custom Input Decoding for details.

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)