163
LE - Encoder Parameters
This parameter selects the output ppr for the encoder output channel X3B.
Function: Settings: Description: NUM
Source
Channel 1 The increments of the encoder at Channel
1 (X3A) are output via encoder emulation at
Channel 2 (X3B).
When Source = Channel 1 is selected, the
emulated encoder output can be further
divided by the Division factor.
0
Channel 2 This value has no function since there is no
encoder interface with encoder emulation
available via Channel 1 (X3A).
1
Actual
Value
The increments of the encoder, whether
measured or calculated (eg. LE08 Encoder
1 Scaling), are output via the emulation at
Channel 2 (X3B).
When Source = Actual Value, the increments
per revolution of the output emulation must
be selected from Actual Value.
2
Reserved - 3
Actual
Value
256 The number of increments per revolution
which are output via encoder emulation at
Channel 2 (X3B) when Source = Actual
Value.
0
512 4
1024 8
2048 12
Division
Direct
The increments of the encoder Channel 1
(X3A) are output directly at Channel 2 (X3B).
Always use this adjustment if Source = Actual
Value.
0
2 The increments of encoder Channel 1 (X3A)
can be divided and output via encoder
emulation at Channel 2 (X3B) by the selected
factor when Source = Channel 1.
16
4 32
8 48
16 64
32 80
64 96
128 112
Default = Channel 1+256 inc + Direct (0)
LE35
Encoder 2 Output PPR

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals