170
LS - Speed Prole Parameters
Preset proles, LS15-LS17
Preset prole settings are available for selection based on type of desired
prole. The presets will automatically adjust the acceleration, deceleration
and jerk rates for a corresponding speed selection. ‘Soft’ settings will have a
relaxed prole, while ‘Hard’ settings will have quicker, more aggressive rates.
If changes are made to any of the pre-settings, the option will reect this by
displaying ‘Custom’ to indicate changes have been made.
Settings: NUM
Default = Custom (0)
Custom 0
Soft 1
Medium 2
Hard 3
Prole Mode (High Speed Prole only)
External Prole 0
Internal Prole 4
Default = Custom (0)
When US04 Control Type = Bi-polar Analog Speed (3), Absolute Analog
Speed (2), Serial Speed DIN66019 Service 49 (4), Serial Speed DIN66019
Service 50 (5) , the speed prole is generated externally by the controller
and the drive’s ramp generator is turned off. It is possible to override the
external prole and utilize the drive’s internal prole with LS15 = Internal
Prole; refer to LS15 for additional information. When US04 Control Type
= Binary Speed Selection (1), Digital Speed Selection (0), or Serial Binary
Speed DIN66019 Service 50 (6), only Internal Prole Mode is actually used
and setting for External Prole in LS15 is ignored.
Preset speed prole for High Speed prole.
Additionally, there is the option Internal Prole (4), in which the High Speed
prole settings LS20-25 can be used to limit the rates of externally generated
speed proles from analog or serial speed control modes. That is, the prole
will be generated by the drive when the rates are less than those dictated by
the controller.
Preset speed prole for One Floor Speed proles (Intermediate Speeds 1
and 2).
Preset speed prole for Emergency Speed prole (Intermediate Speed 3 or
Emergency Prole input function).
LS15
High Speed Prole
LS16
One Floor Prole
LS17
Emergency Prole

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals