EasyManua.ls Logo

KEB COMBIVERT F5

KEB COMBIVERT F5
349 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
206
LP - Positioning Parameters
This parameter is used to turn on the One Floor Positioning Control functionality
or to learn the high speed and short oor slowdown distances.
When set to Learn Slowdown, the slowdown for the selected speed (high
speed or short oor) will be measured on the next run. Afterwards, LP01 will
automatically be set for positioning turned on.
This parameter shows the minimum required slow down distance, based
on the adjusted prole (acceleration, jerks, high speed) to slow down from
contract speed.
This value is the actual distance the drive uses to calculate the actual
deceleration prole for High Speed runs.
This value is the actual distance the drive uses to calculate the actual
deceleration prole for short oor runs
LP01
Position Control
LP02
Minimum Slowdown
Distance
LP03
High Speed Slowdown
Distance
LP04
Short Floor Slowdown
Distance

Table of Contents

Other manuals for KEB COMBIVERT F5

Related product manuals