207
LP - Positioning Parameters
The corrective distance can be used to reset the position error as the car comes
to the oor. When the drive sees the leveling zone marker, the position counter
is reset to reect the actual distance entered in this parameter. The controller
passes the leveling zone sensor signal to the drive via an input programmed
as ‘Position Deviation Reset’. Refer to input parameters LI04-11 for further
information on programmable input functions.
With this parameter the amount of stabilized leveling can be adjusted. A value
of zero means no correction, the function is off and the leveling distance is the
distance adjusted in the controller.
A value of 6.0”, the distance of the leveling zone to the dead zone, will provide
no leveling and the system will be on the verge of over shooting the oor.
The optimum adjustment for direction to the oor operation is a value of
5.7”...5.9”. If a little leveling is desired set the value to 5.0”...5.5”.
LS01
LP05 = 5.8 inches
LP05
Correction Distance

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)

Related product manuals