320
Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para. Name
Hex v1.72 Motor/Gear Type
Setting
Options
NUM
Range Units Default
Pass
Level
I IX P PX Min. Max. Imp. Met.
LO01 Output Inversion
1081 do42
None
/O1
/O2
/O1 + /O2
/RLY1
/RLY1 + /O1
/RLY1 + /O2
/RLY1 + /O1 + /O2
/RLY2
/RLY2 + /O1
/RLY2 + /O2
/RLY2 + /O1 + /O2
/RLY2 + /RLY1
/RLY1 + /RLY2 + /O1
/RLY1 + /RLY2 + /O2
/RLY1 + /RLY2 + /O1 + /O2
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
- - - - None OEM
LO05 Output Function O1
1085 -
Off
Fault
Drive Ready
Drive On
Brake Control
At Speed
High Speed
Deceleration Active
Speed for Door Pre-Opening
Leveling Zone
Main Contact Control
Motor Overheat
Cabinet Fan On
Condition 1
NTSD Output
HV On
AFE Enable
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
- - - - At Speed OEM
LO10 Output Function O2
108A - Same as LO05 ““ - - - - Fault OEM
LO15 Output Function RLY1
108F - Same as LO05 ““ - - - - Off OEM
LO20 Output Function RLY2
1094 - Same as LO05 ““ - - - - Drive On OEM
LO30 Data Value 1
109E - - - 1 62 - - OEM
LO31 Condition 1
109F -
<
<=
=
>=
>
< (AbsVal)
= (AbsVal)
> (AbsVal)
0
1
2
3
4
5
6
7
- - - - > OEM
LO32 Comparison Level 1
10A0 - - - -32000.0 32000.0 - - 0.0 OEM
LO20 Output Function RLY2
1094 - Same as LO05 ““ - - - - Drive On OEM
LO30 Data Value 1
109E - - - 1 62 - - OEM
LO31 Condition 1
109F -
<
<=
=
>=
>
< (AbsVal)
= (AbsVal)
> (AbsVal)
0
1
2
3
4
5
6
7
- - - - > OEM
LO32 Comparison Level 1
10A0 - - - -32000.0 32000.0 - - 0.0 OEM
DG01 Input Status
1181h ru21
RO RO RO RO
None
I7
I8
I5
I6
I1
I2
I3
I4
0
1
2
4
8
16
32
64
128
0 255 - - -
DG02 Inverter Status
1182h
ru0
LF99
RO RO RO RO
See Section 6.16 - 0 255 - - -
DG03 Command Speed
1183h
ru2
LF88
RO RO
- -
-4000 4000
rpm
0
RO RO
-500.0 500.0 0.0
DG04 Elevator Position
1184h ru54
RO RO RO RO
- -
-12000.00 12000.00 in. - 0.00
-30480.00 30480.00 - cm 0.00