Hybrid DVR (HD Series)
17
Main Menu > Parameter > Record > Record Schedule (connued)
Q: How to make the DVR to sound a buzzer and the Siren to sound an alarm when the Smoke detector camera detects smoke?
A: Open Main menu > Parameter > Alarm > Sensor Control and congure the following parameters:
1. Channel: Select the channel where the Smoke detector camera is connected.
2. Enable parameters: Set the Status parameter to ON and congure the Buzzer and Siren duraon in seconds and save the sengs.
(3) Camera linked to the PIR Camera: If the PIR camera detects a moon during the me slot that is marked white in the recording schedule, the channel where the
linked camera is connected starts recording, displays an alert message on the screen, displays the channel in a full screen, and sends an alert email.
NOTE: Make sure displaying an alert message, displaying the channel in a full screen, and sending an alert email are enabled for the channel where the linked camera is connected.
Q#1: How to congure the DVR to show an alert message, open the channel in a full screen, and other related funcons?
A: Open Main menu > Parameter > Alarm > Sensor Control and congure the following parameters:
1. Channel: Select the channel where the linked camera is connected.
2. Enable parameters: Check to enable Show Message, Send Email, Full Screen, and other related parameters.
Q#2: How to link a camera to the PIR camera?
A: Open Main menu > Parameter > Alarm > Sensor Control and congure the following parameters:
1. Channel: Select the channel where the PIR camera is connected.
2. Record Channel: Select the channel that you want to link to the PIR camera channel and save the sengs.
3. Channel: Select the channel where is connected the linked camera.
4. Enable parameters: Check to enable Show Message, Send Email, Full Screen, and other related parameters and save the sengs.
NOTE: For PIR, Siren and Smoke detector camera product informaon, please visit the KGUARD ocial webpage at hp://www.kguardsecurity.com/ and search for the
following model names:
- “WP820A“ for PIR camera
- “WR820A“ for Siren camera
- “WS820A“ for Smoke detector camera
• No Record: A me slot marked black means that there is no recording scheduled for the me slot.