Kinco FD3&CD3 User Manual
See chapter 5.7, table5-7
See chapter 5.7, table5-8
Status word of controller
Following error of position
Input pulse amount before electronic
gear
Execute pulse amount after electronic
gear
Real speed, unit: 0.01rpm
Real current in q axis, unit 0.1Arms
warning status word of the encoder:
Bit 0: Battery Warning
Bit 1: Mixed Warning
Bit 2: Encoder Busy
Range: 0-31, current index in the
position table
9.2 F002
This panel menu contains parameters for the control loop settings.
Controller->Panel Menu->Control Loop Setting(F002)
Table 9-2: Panel F002
Save or init parameters
1: save control parameters
10: init control parameters
Bandwidth of the velocity loop,
unit: Hz.
Integral gain of the velocity loop, as a
combination of 32*Kvi(60F9.02) +
Kvi/32(60F9.07). When written, it sets
Kvi(60F9.02)=0 and the value goes to
Kvi/32(60F9.07).