Kinco FD3&CD3 User Manual
28
3.8 Communication setting dial code
The communication ID of the FD3 servo drive can be set through the dial code switch in the panel. After
changing the dial code, restart the drive to take effect.When SW1~SW8 are OFF, the driver reads the
communication ID in EEPROM and the user can modify the device station number (0x2F800108) through
communication.
Table 3-8 Dial code switch description
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
Node ID
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EEPROM
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
4
ON
ON
ON
ON
ON
ON
ON
ON
255